Donny
To make your configuration work, you need t set up your controllers with the protocol that you want them to use. In your case, you will set up the controllers as DMX devices. You want them to output DMX so they need to be configured as DMX. I am not familliar then the Renard devices as far as channel counts so I will assume that it is a 24 channel device. Grab a Lynx 16 channel controler and then reconfigure it to suit your needs. Since it will output DMX it really does not matter what type here. The next thing that you need to do is select what type of protocol it will use. Since you are using it with other DMX over ethernet devices it has to use the same stuff. Set them up as DMX devices. When you set them up select which DMX channel each will start at.
When you configure the output plugin, the DR4 will be programmed for DMX universes. You will have to select DMX universes that match where you put your controllers. It could look like Univierse 1 for DMX channels 1 thru 512 with 512 channels, Universe 2 channels 513 to 1024with 512 channels, Universe 3 1025 to ...
See the attached picture.
dmx CONFIG.JPG
Cheers
Four little words sum up what has lifted most successful individuals over the crowd: a little bit more. They did all that was expected of them and a little bit more.